Conductive conductivity sensor, Media: water and waste water, Cell constant: k=0.1 cm?¹, Measuring range:10 µS/cm-20 mS/cm, Temperature sensor: Pt1000 Class A, Process pressure: 13 bar abs. (20 °C)/1 bar abs. (120 °C), Process temperature: -20-120 °C, Sterilisation: max. 30 min at max. 140 °C, Protection class: IP68, Interfaces: Memosens, Process connection: G 1 or NPT 1
Conductive conductivity sensor, Hygienic, Media: pure and ultrapure water, Cell constant: k=0.1 cm⁻¹, measuring range: 0.04...500 µS/cm, temperature sensor: Pt1000 class A, process pressure: 13 bar (20°C)/9 bar (120°C), process temperature: -5...120°C, sterilisation: max. 45 min at max. 150°C/6 bar abs., protection class: IP68, interfaces: Memosens, Process connection: Clamp ISO2852 G 1/2
Conductive conductivity sensor, Hygienic, Media: pure and ultra-pure water, Cell constant: k=0.1 cm??¹, Measuring range: 0.04-500 µS/cm, temperature sensor: Pt1000 class A, process pressure: 13 bar (20 °C)/9 bar (120 °C), process temperature: -5-120 °C, sterilisation: max. 45 min at max. 150 °C/6 bar abs., protection class: IP68, interfaces: Memosens, Process connection: Varivent/Neumo BioControl/Clamp
Conductive conductivity sensor, Hygienic, Media: pure and ultra-pure water, Measuring range A: k=0.01: 0.04-20 µS/cm, Measuring range B: k=0.1: 0.10-200 µS/cm, Temperature sensor: Pt1000 Class A, Process pressure: 13 bar abs. (20 °C)/1 bar abs. (120 °C), Process temperature: -20-120 °C, Sterilisation: max. 30 min at max. 140 °C, Protection rating: IP68, Interfaces: Memosens,
pH and redox sensor, Measuring range A: pH 1-12, Measuring range B: pH 0-14, Redox measuring range: -1,500-1,500 mV, Process pressure: 0.8-17 bar abs, Process temperature of pH measuring range A: -15-80 °C, Process temperature of pH measuring range B: 0-135°C, Temperature sensor: NTC 30K, Shaft length: 120/225/360/425 mm, Protection rating: IP68, Interfaces: Memosens, Process connection: Pg 13.5
pH sensor, Measuring range A: pH 1 - 12, Measuring range B: pH 0-14, Measuring range F: pH 0-10, Process pressure of measuring range A and B: 0.8-17 bar abs., Process pressure of measuring range F: 0.8-7 bar abs., Process pressure of measuring range A: -15-80 °C, Process temperature of measuring range B: 0-135°C, Process temperature of measuring range C: 0-70 °C, Temperature sensor: NTC 30K, Shaft length: 120/225/360/425 mm, Protection rating: IP68, Interfaces: Memosens, Process connection: Pg 13.5
Inductive conductivity sensor, Hygienic, Cell constant: k=11.0 cm?¹, Measuring range: 200 µS/cm-1,000 mS/cm, Temperature sensor: Pt1000 Class B, Process pressure: 13 bar abs. (50 °C)/6.6 bar abs. (130 °C), Process temperature: -10-110 °C, Sterilisation: max. 60 min at max. 130 °C, Protection rating: IP69K, Output: 4-20 mA, Interface: IO-Link (optional)
pH sensor, measuring range: 1-12 pH, process pressure: 1-17 bar abs., Process temperature: –15- 80 °C, Temperature sensor: NTC 30K, Shaft length: 120 mm, Protection rating: IP68, Interfaces: Memosens, Process connection: Pg 13.5
Conductive conductivity sensor,Media: water and waste water, Cell constant: k=0.1 cm⁻¹, measuring range: 10 µS/cm...20 mS/cm , temperature sensor: Pt1000 class A, process pressure: 13 bar abs. (20°C)/1 bar abs. (120°C), process temperature: -20...120°C, sterilisation: max. 30 min at max. 140°C, protection class: IP68, interfaces: Memosens, Process connection: G 1
Conductive conductivity sensor, Hygienic, Media: pure and ultrapure water, Cell constant: k=0.01 cm⁻¹, measuring range: 0.04...20 µS/cm, sensor: Pt1000 class A, process pressure: 13 bar abs. (20°C)/1 bar abs. (120°C), process temperature: -20...120°C, sterilisation: max. 30 min at max. 140°C, protection class: IP68, interfaces: Memosens, Process connection: NPT 1/2, connection: measuring cable CYK10
pH sensor, Measuring range: 0-14 pH, Process pressure: 1-17 bar abs., Process temperature: 0- 135 °C, Temperature sensor: NTC 30K, Shaft length: 120 mm, Protection rating: IP68, Interfaces: Memosens, Process connection: Pg 13.5
Conductive conductivity sensor, Hygienic, Media: pure and ultrapure water, Cell constant: k=0.1 cm⁻¹, measuring range: 0.10...200 µS/cm, temperature sensor: Pt1000 class A, process pressure: 13 bar abs. (20°C)/1 bar abs. (120°C), process temperature: -20...120°C, sterilisation: max. 30 min at max. 140°C, protection class: IP68, interfaces: Memosens, process connection: NPT 1/2