Conductive point level switch, Output: 2 x SPDT relay, Process temperature range: -20–60°C, Auxiliary power: 85–253 V AC/20–30 V AC/20–60 V DC, Protection rating: IP66
Conductive level detector, Media: liquid with minimum conductivity of up to 10 µS/cm, Max. probe length: 15 m, Output: PNP/Relay/NAMUR/separate electronic, Process pressure range: -1–10 bar, Measuring points: 2/3/5, Process temperature range: -40–70 °C, Protection rating: IP66
Capacitive level sensors, Media: liquid with minimum conductivity of up to 100 µS/cm , Max. probe length: 2,500 mm, Output: 4-20 mA, Process pressure range: -1–10 bar, Process temperature range: -40–100 °C, Measuring accuracy: ± 1 %, Probe material: stainless steel (1.4404) or carbon fibre, Enclosure material: polyester, Protection rating: IP66, With overfill protection as per WHG
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67, Process connection: G1, Connection: M12 plug connection
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 5,000 mm, Measurement point: 3 x rod (316Ti), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 4-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67, Process connection: G3/4, Connection: M12 plug connection
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65, Process connection: G1, Connection: M16 valve connector ISO4400
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 1,000 mm, Measurement point: 3 x rod (stainless steel), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 1,000 mm, Measurement point: 2 x rod (stainless steel), Output: FEW54, 3-wire, Power supply: 20–253 V AC/20–55 V DC, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 1,000 mm, Measurement point: 3 x rod (stainless steel), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland, Water Resources Act (WHG)/leakage monitoring
Conductive point level switch, Functions: two-channel fill-level analysis / level / switch delay / two-point control, Switching output: 1 x Relay SPDT, Auxiliary energy: 20–30 V AC/20–60 V DC, Dimensions: 35 x 99 x 102.5 mm, Operating temperature: -20–60 °C, Mounting: DIN 35 rails
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 5,000 mm, Measurement point: 5 x rod (316Ti), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 2,000 mm, Measurement point: 5 x rod (stainless steel), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland, Water Resources Act (WHG)/leakage monitoring
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 500 mm, Measurement point: 2 x rod (stainless steel), Output: FEW54, 3-wire, Power supply: 20–253 V AC/20–55 V DC, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Conductive point level switch, Functions: two-channel level measurement / level limit / switch delay / two-point control, Switching output: 2 x SPDT relays, Power Supply: 85-253 V AC, Dimensions: 35 x 99 x 102.5 mm, Operating temperature: -20–60 °C, Mounting: DIN 35 rails
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, IO-Link, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65, Process connection: G1/2, Connection: M16 valve connector ISO4400
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67, Process connection: G3/4, Connection: M12 plug connection
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 5,000 mm, Measurement point: 3 x rod (316Ti), Output: FEW54, Relay, 3-wire, Power supply: 20–253 V AC/20–55 V DC, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland