Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.1–75 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 3/4, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: FKM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 1.5–750 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 2, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: EPDM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.2–150 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 1, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: FKM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.2–100 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 1, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: EPDM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.05–35 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 1/2, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: FKM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Electromagnetic flow meter, Medium: conductive liquids, Measurement range: 2.23-1112.60 l/min, Measurement accuracy: ± 1 %, Reproducibility: ± 0.5%, Max. operating pressure: 10 bar at 23°C, Process temperature range: 0-60°C, Digital outputs: 2 (Frequency up to 1,500 Hz, S3L), Analog outputs: 1 (4-20 mA), Protection rating: IP65, Power cable: 7.6 m (2-wire/shielded), Output signal cable: 7.6 m (5-wire/shielded), Configuration via Bluetooth
Electromagnetic flow meter, Medium: conductive liquids, Measurement range: 1.36-662.34 l/min, Measurement accuracy: ± 1 %, Reproducibility: ± 0.5%, Max. operating pressure: 10 bar at 23°C, Process temperature range: 0-60°C, Digital outputs: 2 (Frequency up to 1,500 Hz, S3L), Analog outputs: 1 (4-20 mA), Protection rating: IP65, Power cable: 7.6 m (2-wire/shielded), Output signal cable: 7.6 m (5-wire/shielded), Configuration via Bluetooth