Electromagnetic flow meter, Medium: conductive liquids, Measurement accuracy: ± 0.5 % of the measurement value, Max. process pressure: PN40/Class300/20K, Nominal size range: DN15 - DN600, Lining: PFA or PTFE, Electrode: 1.4435 (316L)/Alloy C22/2.4602/Tantalum/Platinum/Titanium, Process temperature range with PFA lining: -20-150 °C, Process temperature range with PTFE lining: -40-130 °C
Electromagnetic flow meter, Medium: conductive liquids, Measurement accuracy: ± 0.5 % of the measurement value, Max. process pressure: PN40/Class300/20K, Nominal size range: DN25 - DN4000, Process temperature range with hard rubber lining: 0-80 °C, Process temperature range with polyurethane lining: -20-50 °C, Process temperature range with PTFE lining: -20-90 °C, Electrode: 1.4435 (316L)/Alloy C22
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 1.5–750 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 2, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: FKM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.2–150 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 1, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: FKM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.05–35 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 1/2, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: FKM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.1–75 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 3/4, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: FKM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.1–75 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 3/4, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: EPDM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.2–100 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 1, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: EPDM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 1.5–750 l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 2, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: EPDM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Volumetric flow meter, Medium: conductive liquids, Volume flow/temperature/batch counter, Measuring range: 0.05–35l/min, Measurement accuracy: ± 0.8 %, Pressure measurement range max. 16 bar, Medium temperature: -10–70 °C, Process connection: G 1/2, IO-Link, NO/NC, OUT 1: pulse/frequency/switch output, OUT 2: 4–20 mA/2–10 V, Power supply: 18–30 V DC, Seal material: EPDM, Connection: M12 connector, Bluetooth® for start-up, Operation and maintenance via free SmartBlue app
Our online store uses cookies to help us improve our offer and provide the best possible service to our customers. By clicking "Accept" you agree to our cookie policy.
Cookies for tools that collect anonymous data about website usage and functionality. We use the insights to improve our products, services and user experience.
Advertising
Cookies for anonymous information that we collect to recommend useful products and service to you.
Essential cookies
Cookies for tools that enable essential services and functions. This option cannot be declined.