Radar level sensor, Media: liquids or bulk solids, Max. measuring range: 20 m in liquids/10 m in bulk solids, Measurement accuracy: +/- 2 mm, Process connection: thread/collar flange, Process pressure range: -1-3 bar, Process temperature range: -40-80 °C, Cable length: configurable
Guided radar level sensor, for high temperature and high pressure, Media: liquids, Max. measuring range of rod probe: 10 m, Max. measuring range of rope probe: 45 m, Max. measuring range of coax. probe: 6 m, Process connection: thread/collar flange, Interface: HART/PROFIBUS PA/FOUNDATION Fieldbus/Bluetooth, Process pressure range: -1-40 bar, Process temperature range: -50-200 °C
Guided radar level sensor, Media: liquids/pastes/slurries, Max. measuring range of rod probe: 4 m, Max. measuring range of rope probe: 12 m, Process connection: thread/collar flange, Interface: HART/PROFIBUS PA/FOUNDATION Fieldbus/Bluetooth, Process pressure range: -1-6 bar, Process temperature range: -20-80 °C
Radar level sensor, Max. measurement range: liquids 8 m, Output: 4-20 mA, 2-woire, Bluetooth (App)., Process pressure range: -1–3 bar, Process temperature range: -40–60°C, Protection rating: IP66
Radar level sensor, Media: liquid, Measurement range: 8 m, Output: 4–20 mA, 2-wire, Bluetooth (app), Process connection front: G 1 1/2, Process connection rear: G 1, Process pressure range: 1–3 bar, Process temperature range: -40–60 °C, Cable length: 10 m
Radar level sensor, Media: liquids/bulk solids, Max. measuring range: 15 m, Output: 4-20 mA/HART, 2-core, Process connection: G 1 1/2, Process pressure range: -1-3 bar, Process temperature range: -40-80 °C, Connection: PUR cable (10 m)
IIOT radar level transmitter, Medium: liquids/bulk solids, Measuring range: up to 15 m, Accuracy: ± 10 mm, Process temperature range: -20-60 °C, Measuring interval: 1 min-24 h (selectable), Battery powered with wireless and mobile connectivity (> 10 years battery life), Communication: SIM card with secured configuration (NB-IoT, LTE-M with 2G replacement), Material: PBT/PC, Protection rating: IP66/IP68, Mounting: mounting bracket IBC/vertical tube
Wireless radar level sensor, Medium: liquids/bulk solids, Measuring range max.: 5 m, Accuracy: up to 2 mm, Measuring interval: 15 min–24 h (selectable), Battery-powered with wireless compatibility, Battery output: 8.5 Ah, Connectivity: 4G/LTE-M with 2G Fallback, Incl. SIM card, Process temperature range: -40–60 °C, Material: ASA/PA/Stainless steel (316L), Protection class: IP68
Wireless radar level sensor, Medium: liquids/bulk solids, Measuring range max.: 5 m, Accuracy: up to 2 mm, Measuring interval: 15 min–24 h (selectable), Battery-powered with wireless compatibility, Battery output: 8.5 Ah, Connectivity: 4G/LTE-M with 2G Fallback, Incl. SIM card, Process temperature range: -40–60 °C, Process connection: G 2, Material: ASA/PA/Stainless steel (316L), Protection class: IP68
IIOT radar level transmitter, Medium: liquids/bulk solids, Measuring range: up to 15 m, Accuracy: ± 10 mm, Process temperature range: -20-60 °C, Measuring interval: 1 min-24 h (selectable), Battery powered with wireless and mobile connectivity (> 10 years battery life), Communication: SIM card with secured configuration (NB-IoT, LTE-M with 2G replacement), Material: PBT/PC, Protection rating: IP66/IP68, Mounting: alignable wall/ceiling
Electronic level sensor, Guided wave radar, 4 x NC/NO programmable, DC PNP, Process connection: G 3/4 male, Probes up to 1,600 mm, Protection rating: IP67, M12 connector
Radar level sensor, media: liquids, measuring range max: 15 m, output: 4-20 mA HART, front process connection: G 1 1/2 male thread, rear process connection: G 1 male thread, process pressure range: -1...3 bar, process temperature range: -40...80 °C, interfaces: Bluetooth (app), cable length: 10 m
Radar level sensor, media: bulk solids, measuring range max: 10 m, output: 4-20 mA HART, front process connection: customer-side mounting device without flange, rear process connection: G 1, process pressure range: -1...3 bar, process temperature range: -40...80 °C, cable length: 10 m
Hygienic radar level sensor, Media: liquids, Max. measuring range: 10 m, Outputs: 1 x 4-20 mA; 1 x PNP/NPN, Process connection: G 1 external thread Aeptoflex Vario, Pressure resistance: 8 bar, Process temperature range: -40-150 °C, Interfaces: IO-Link, Electrical connection: M12 plug connection
Radar level sensor, media: liquids, measuring range max: 20 m, output: 4-20 mA HART, front process connection: customer-side mounting device, rear process connection: G 1, process pressure range: -1...3 bar, process temperature range: -40...80 °C, cable length: 10 m
Electronic level sensor, Guided wave radar, 2 x NC/NO programmable, DC PNP, Process connection G 3/4 male, Probes up to 1,600 mm, Protection rating: IP67, M12 connector
Radar level sensor, Medium: liquids/bulk solids, Measuring range max.: 5 m, Accuracy: up to 2 mm, Measuring interval: 15 min–24 h (selectable), Battery-powered with wireless compatibility, Battery output: 8.5 Ah, Connectivity: 4G/LTE-M with 2G Fallback, Incl. SIM card, Process temperature range: -40–60 °C, Process connection: G 2, Material: ASA/PA/Stainless steel (316L), Protection class: IP68
Radar level sensor, Media: liquids/bulk solids, Max. measuring range: 120 m, Output: 4-20 mA/HART, 2-core, Display/operating module: PLICSCOM with Bluetooth, Process connection: Horn antenna, plastic single-chamber, Process pressure range: -1-2 bar, Process temperature range: -40-80 °C, Connection: M20 x 1.5 cable gland
Radar level sensor, media: liquids, measuring range max: 20 m, output: 4-20 mA HART, interface: Bluetooth (App), front process connection: customer-side mounting device, rear process connection: G 1 male thread, process pressure range: -1...3 bar, process temperature range: -40...80 °C, interfaces: Bluetooth, cable length: 10 m
Radar level sensor, media: liquids, measuring range max: 15 m, output: 4-20 mA HART, front process connection: G 1 1/2, rear process connection: G 1, process pressure range: -1...3 bar, process temperature range: -40...80 °C, interfaces: HART, cable length: 10 m
Radar level sensor, Media: liquids/bulk solids, Max. measuring range: 8 m, Output: 4-20 mA, 2-core, Process connection: G 1 1/2, Process pressure range: -1-3 bar, Process temperature range: -40-80 °C, Connection: PVC cable (10 m)
Electronic level sensor, Guided wave radar, NC/NO programmable + analogue 4-20 mA or 0-10 V, DC PNP, Process connection: G 3/4 male, Probes up to 1,600 mm, Protection rating: IP67, M12 connector