Siemens

Residual protective devices Siemens 5SU1356-6KK16

extended guarantee
Item number: 101147
EAN: 4001869306728
  • RCBO
  • Type A
  • 1 + N pole
  • 230 V
  • B 16 A
  • IF 30 mA
  • 6 kA
27,00
plus VAT plus dispatch
Shipping today
cccvde
Corresponding accessories
Pin busbar Siemens 5ST3623
Pin busbar, 10 mm², 2 x 3 x 1-phase + N, 80 A, Safe-to-touch for RCCB/CB combinations
Item number: 101156
RRP: 12,50
8,20
plus VAT plus dispatch
in stock
Shipping today
Corresponding accessory groups
DIN rail PHOENIX 1207640 - NS 35/7,5 PERF 755MM
DIN rail, Material: Steel galvanized and passivated with a thick layer, Perforated, Height: 7.5 mm, Width: 35 mm, Length: 755 mm
Item number: 100853
- 32 % RRP: 2,96
2,00
plus VAT plus dispatch
in stock
Shipping today
DIN rail PHOENIX 1207653 - NS 35/7,5 PERF 955MM
DIN rail, Material: Steel galvanized and passivated with a thick layer, Perforated, Height: 7.5 mm, Width: 35 mm, Length: 955 mm
Item number: 100854
- 31 % RRP: 3,76
2,60
plus VAT plus dispatch
in stock
Shipping today
DIN rail PHOENIX 1207679 - NS 35/15 PERF 755MM
DIN rail, Material: Steel galvanized and passivated with a thick layer, Perforated, Height: 15 mm, Width: 35 mm, Length: 755 mm
Item number: 100851
- 31 % RRP: 4,91
3,40
plus VAT plus dispatch
in stock
Shipping today
DIN rail PHOENIX 1207682 - NS 35/15 PERF 955MM
DIN rail, Material: Steel galvanized and passivated with a thick layer, Perforated, Height: 15 mm, Width: 35 mm, Length: 955 mm
Item number: 100852
- 31 % RRP: 6,22
4,30
plus VAT plus dispatch
in stock
Shipping today
Din rails close

Technical details
General data

Residual protective devices
1+N
B
A

Electrical data

AC
30 mA
230 V
16 A
6 kA
1 kA

Mechanical data

36 mm
90 mm
77 mm
2 MW
70 mm

Ambient conditions

-25 °C
55 °C
IP20
10000

Further information

CCC, GOST, IMQ, VDE, ÖVE

Classification

85362010

Product description
Residual protective devices Siemens 5SU1356-6KK16
The 5SU1356-6KK16 residual current operated circuit breaker with overcurrent protection from Siemens uses a rated voltage of 230 V and a rated current of 16 A with tripping characteristic type B and is short-circuit proof up to 6 kA. The RCBO features 1 + N poles. Thanks to the type A design, the residual current operated circuit breaker with overcurrent protection 5SU1356-6KK16 trips in the event of sinusoidal AC residual currents and pulsating DC residual currents. The residual current operated circuit breaker with overcurrent protection 5SU1356-6KK16 with a rated residual current of max. 30 mA is used for personnel, material and fire protection as well as for additional protection against direct contact. It is used for building management systems, industrial applications or machine and plant construction.