Temperature signal conditioner, Records (2-/3-/4-wire) Pt sensors and resistors up to 4.5 kOhm, Output signal current: 0-10 mA; 2-10 mA; 0-20 mA; 4-20 mA, Output signal voltage: 0-5 V; 1-5 V; 0-10 V; 2-10 V, Calibrated measurement range switching, Detect wire break/sensor short circuit Overrange and underrange, Switchable clipping, Limits the standard analogue signal to the upper range values, Setting: DIP switch, Supply voltage: 24 V DC: Test voltage: 2.5 kV, Connection: Push-in, Mounting: DIN-rail 35 mm
Current signal conditioner, Detection of AC and DC currents, Input signal current: AC/DC 0-1 A (IN 1); AC/DC 0-5 A (IN 2), Output signal current: 0-10 mA; 2-10 mA; 0-20 mA; 4-20 mA, Output signal voltage: 0-5 V; 1-5 V; 0-10 V; 2-10 V, Frequency range: 16-400 Hz, True RMS measurement, Calibrated measurement range switching, Selectable filter function, Setting: Software or DIP switch, Supply voltage: 24 V DC: Test voltage: 2.5 kV, Connection: Push-in, Mounting: DIN-rail 35 mm
Frequency signal conditioner, Detection of NAMUR, NPN or PNP sensors, Frequency measuring range: 0.1 Hz-120 kHz; 0.1 Hz-1 kHz; 0.1 Hz-20 kHz, Calibrated measurement range switching, Setting: Software or DIP switch, Supply voltage: 24 V DC: Test voltage: 2.5 kV, Connection: Push-in, Mounting: DIN-rail 35 mm
Voltage signal conditioner, Detection of millivolt signals, Input signal voltage:± 100 mV; 0-200 mV; 0-300 mV, Output signal current: 0-10 mA; 2-10 mA; 0-20 mA; 4-20 mA, Output signal voltage: 0-5 V; 1-5 V; 0-10 V; 2-10 V, Calibrated measurement range switching, Switchable clipping, Limits the standard analogue signal to the upper range values, Setting: Software or DIP switch, Supply voltage: 24 V DC: Test voltage: 2.5 kV, Connection: Push-in, Mounting: DIN-rail 35 mm
JUMPFLEX® transducer, Threshold value switch for analogue signals, Monitoring of standard analogue signals and reporting of signal statuses, 1 x DO, 1 x changeover contact, Input signal current: ±20 mA, Input signal voltage: ± 10 V; 0-30 V, Calibrated measurement range switching, Setting: Software/"Teach-in"-Funktion/DIP switch, Supply voltage: 24 V DC: Test voltage: 2.5 kV, Connection: Push-in, Mounting: DIN-rail 35 mm
JUMPFLEX®-Temperature signal conditioner, Detection of KTY sensors (2-wire), Input voltage: ± 30 V DC, Output signal current: 0-10 mA; 2-10 mA; 0-20 mA; 4-20 mA, Output signal voltage: 0-5 V; 1-5 V; 0-10 V; 2-10 V, Calibrated measurement range switching, DIP switch, Clipping capability, Limits the standard analogue signal to the upper range values, Supply voltage: 24 V DC: Test voltage: 2.5 kV, Connection: Push-in, Mounting: DIN-rail 35 mm
Temperature signal conditioner, Records type J and K thermocouples, Temperature measuring range: -150-1,200 °C (Typ J)/-150-1,350 °C (Typ K), Output signal current: 0-10 mA; 2-10 mA; 0-20 mA; 4-20 mA, Output signal voltage: 0-5 V; 1-5 V; 0-10 V; 2-10 V, Calibrated measurement range switching, Detect wire break/sensor short circuit Overrange and underrange, Cold junction compensation on/off, Switchable clipping, Limits the standard analogue signal to the upper range values, Setting: DIP switch, Supply voltage: 24 V DC: Test voltage: 2.5 kV, Connection: Push-in, Mounting: DIN-rail 35 mm
Our online store uses cookies to help us improve our offer and provide the best possible service to our customers. By clicking "Accept" you agree to our cookie policy.
Cookies for tools that collect anonymous data about website usage and functionality. We use the insights to improve our products, services and user experience.
Advertising
Cookies for anonymous information that we collect to recommend useful products and service to you.
Essential cookies
Cookies for tools that enable essential services and functions. This option cannot be declined.