Monitoring relay for 1 phase networks, Features: Overcurrent monitoring (OVER)/Overcurrent monitoring with fault latch (OVER+LATCH)/Undercurrent monitoring (UNDER)/Undercurrent monitoring with fault latch (UNDER+LATCH)/Monitoring the window between Min and Max (WIN)/Monitoring the window between Min and Max with fault latch (WIN+LATCH), Tripping delay: 0.1-10 s/Start-up suppression time: 0-10 s, 2 x change over contacts, Fusing: 10 A, 24-240 V AC/DC, Terminal connection
Monitoring relay, Pump up or minimum monitoring (Pump up)/Pump down or maximum monitoring (Pump down), Time functions: Start-up delay (Delay ON)/Turn-off delay (Delay OFF) fixed 5 s, 1 x changeover, 230 V AC, Terminal connection
Monitoring relay, Pump up; Min and Max-Alarm/ Pump down; Min and Max-Alarm/Pump up and down; Min-Alarm/Pump up and down; Max-Alarm/Pump up/Pump down/Pump up with 2 pumps/Pump down with 2 pumps/Well control; Min-Alarm/Level code, Time features: 1-10 s, 3 x NO (with common root), 24-240 V AC/DC, 4 probe inputs for level detection, Adjustable sensor voltage, Terminal connection
Monitoring relay for 1 phase networks, Fusing: 8 A fast acting, Features: Undervoltage monitoring (U)/Window function (WIN), Time functions: Start-up delay approx. 300 ms/Tripping delay 0.1-10 s, 1 x changeover contact, 24 V DC/230 V AC/DC, Terminal connection
Monitoring relay for 3 phase networks, Fusing: 5 A fast acting, Features: Undervoltage monitoring (UNDER)/Undervoltage and phase sequence monitoring (UNDER+SEQ)/Monitoring of the window between Min and Max (WIN)/Monitoring of the window between Min and Max and monitoring of phase sequence (WIN+SEQ), Tripping delay: 0.1-10 s, 2 x changeover contacts, 24-240 V AC/DC, Terminal connection
Monitoring relay for 1 and 3 phase networks, Features: Voltage monitoring with adjustable thresholds/adjustable tripping delay/monitoring of phase failure; Phase sequence and asymmetry with adjustable asymmetry/Undervoltage monitoring (UNDER)/Undervoltage monitoring and monitoring of phase sequence (UNDER+SEQ)/Monitoring the window between Min and Max (WIN)/Monitoring of the window between Min and Max and monitoring of phase sequence (WIN+SEQ), Tripping delay: 0-30 s, 2 x change over contacts, Rated voltage: 250 V AC, Terminal connection
Monitoring relay, Features: Temperature monitoring of the motor winding (max. 6 PTC) with fault latch for temperature sensors in accordance with DIN 44081/Short circuit monitoring of the thermistor circuit (selectable via terminals)/Test function with integrated reset button, 1 changeover contact, 230 V AC, Terminal connection
Monitoring relay for 1 phase networks, Features: Overcurrent monitoring (OVER)/Overcurrent monitoring with fault latch (OVER+LATCH)/Undercurrent monitoring (UNDER)/Undercurrent monitoring with fault latch (UNDER+LATCH)/Monitoring the window between Min and Max (WIN)/Monitoring the window between Min and Max with fault latch (WIN+LATCH), Tripping delay: 0.1-10 s/Start-up delay approx. 300 ms, 1 x changeover contact, 24-240 V DC/110-240 V AC, Terminal connection
Monitoring relay for 1 phase networks, Fusing: 5 A, Features: Overcurrent monitoring (OVER)/Overcurrent monitoring with fault latch (OVER+LATCH)/Undercurrent monitoring (UNDER)/Undercurrent monitoring with fault latch (UNDER+LATCH)/Monitoring the window between Min and Max (WIN)/Monitoring the window between Min and Max with fault latch (WIN+LATCH), Tripping delay: 0.1-10 s/Start-up suppression time: 0-10 s, 2 x change over contacts, 24-240 V AC/DC, Terminal connection
Monitoring relay, Features: Temperature monitoring of the motor winding (max. 6 PTC) with fault latch for temperature sensors in accordance with DIN 44081/Test function with integrated test or reset button/Basic function (Off)/Short-circuit monitoring of the thermistor circuit (+ K)/Zero-voltage protection (+ N)/Short-circuit monitoring and zero-voltage protection (+ K + N), 2 x change over contacts, 24-240 V AC/DC, Terminal connection
Monitoring relay for 1 and 3 phase networks, Features: Undervoltage monitoring (UNDER)/Undervoltage and phase sequence monitoring (UNDER+SEQ)/Monitoring of the window between Min and Max (WIN)/Monitoring of the window between Min and Max and monitoring of phase sequence (WIN+SEQ), Tripping delay: 0-10 s, 1 x changeover contact, Rated voltage: 250 V AC, Terminal connection
Monitoring relay for 1-phase networks, Built-in current transformer, 2 x changeover, 24-240 V AC/DC, Terminal connection, Time functions: Start-up delay approx. 300 ms fix; Tripping delay 0.1-10 s; Start-up suppression 0-10 s, Number of functions: 8, Features: Overcurrent monitoring (O)/Undercurrent monitoring (U)/Window function (W)/Under- and overcurrent with separate relay outputs (MM)/Maximum monitoring (2MAX)/Fault memory (+ L)
Monitoring relay for 3 phase networks, Features: Undervoltage monitoring for AC voltage in 3-phase networks/Phase sequence/Phase failure and asymmetry monitoring with adjustable asymmetry, Connection of the neutral conductor optional, Tripping delay: fixed/approx. 100 ms, Rated voltage: 250 V AC, 1 x Change over contact, Terminal connection
Our online store uses cookies to help us improve our offer and provide the best possible service to our customers. By clicking "Accept" you agree to our cookie policy.
Cookies for tools that collect anonymous data about website usage and functionality. We use the insights to improve our products, services and user experience.
Advertising
Cookies for anonymous information that we collect to recommend useful products and service to you.
Essential cookies
Cookies for tools that enable essential services and functions. This option cannot be declined.