Turbine flow sensor, Internal diameter: 9.3 mm, Linear measurement range: 1-20 l/min, Min measurement range: 0.5 l/min, Reproducibility: <0.15 %, Material in contact with the medium: SS316L/PVDF/FPM/Ruby, Seal: FPM (EPDM optional), Length: 81 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 4,800
Turbine flow sensor, Internal diameter: 4.6 mm, Linear measurement range: 0.1-2 l/min, Min measurement range: 0.03 l/min, Reproducibility: <0.15 %, Material in contact with the medium: PVDF/Ruby, Length: 53 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 100,000
Turbine flow sensor, Internal diameter: 4.6 mm, Linear measurement range: 0.07-1 l/min, Min measurement range: 0.02 l/min, Reproducibility: <0.15 %, Material in contact with the medium: SS316L/PVDF/FPM/Ruby, Seal: FPM (EPDM optional), Length: 69 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 130,000
Turbine flow sensor with single-use PVDF measurement tube, Internal diameter: 9.3 mm, Linear measurement range: 1-20 l/min, Min measurement range: 0.5 l/min, Reproducibility: <0.15 %, Material in contact with the medium: PVDF/Ruby, Length: 62 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 4,800
Turbine flow sensor, Internal diameter: 9.3 mm, Linear measurement range: 1-20 l/min, Min measurement range: 0.5 l/min, Reproducibility: <0.15 %, Material in contact with the medium: SS316L/PVDF/FPM/Ruby, Seal: FPM (EPDM optional), Length: 78 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 4,800
Turbine flow sensor with single-use PVDF measurement tube, Internal diameter: 4.6 mm, Linear measurement range: 0.01-2 l/min, Min measurement range: 0.03 l/min, Reproducibility: <0.15 %, Material in contact with the medium: PVDF/Ruby, Length: 53 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 100,000
Turbine flow sensor, Internal diameter: 14 mm, Linear measurement range: 2.5-40 l/min, Min measurement range: 1.5 l/min, Reproducibility: <0.15 %, Material in contact with the medium: SS316L/PFA/FPM/Ruby, Seal: FPM (EPDM optional), Length: 70 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 2,000
Turbine flow sensor, Internal diameter: 14 mm, Linear measurement range: 2.5-40 l/min, Min measurement range: 1.5 l/min, Reproducibility: <0.15 %, Material in contact with the medium: SS316L/PFA/FPM/Ruby, Seal: FPM (EPDM optional), Length: 72 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 2,000
Turbine flow sensor with single-use PVDF measurement tube, Internal diameter: 4.6 mm, Linear measurement range: 0.07-1 l/min, Min measurement range: 0.02 l/min, Reproducibility: <0.15 %, Material in contact with the medium: PVDF/Ruby, Length: 53 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 130,000
Fixed PVDF turbine flow sensor, Internal diameter: 9.3 mm, Linear measurement range: 1-20 l/min, Min measurement range: 0.5 l/min, Reproducibility: <0.15 %, Material in contact with the medium: PVDF/Ruby, Length: 62 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 4,800
Turbine flow sensor, Internal diameter: 16 mm, Linear measurement range: 6.6 – 66 l/min, Measurement accuracy: 0.5% of the measured value at 1-5 cSt, Material in contact with the medium: stainless steel/ceramic (wolfram carbide), Viscosity linear range: 1 – 5 cSt, Other viscosities: 8/12/20 cst, Output module: IC-MV-PO with PNP/NPN, Cable length: 5 m
Turbine flow sensor, Internal diameter: 25 mm, Linear measurement range: 26 – 266 l/min, Measurement accuracy: 0.5% of the measured value at 1-5 cSt, Material in contact with the medium: stainless steel/ceramic (wolfram carbide), Viscosity linear range: 1 – 5 cSt, Other viscosities: 8/12/20 cst, Output module: IC-MV-PO with PNP/NPN, Cable length: 5 m
Turbine flow sensor, Internal diameter: 40 mm, Linear measurement range: 56 – 566 l/min, Measurement accuracy: 0.5% of the measured value at 1-5 cSt, Material in contact with the medium: stainless steel/ceramic (wolfram carbide), Viscosity linear range: 1 – 5 cSt, Other viscosities: 8/12/20 cst, Output module: IC-MV-PO with PNP/NPN, Cable length: 5 m
Turbine flow sensor, Internal diameter: 4.6 mm, Linear measurement range: 0.1-2 l/min, Min measurement range: 0.03 l/min, Reproducibility: <0.15 %, Material in contact with the medium: SS316L/PVDF/FPM/Ruby, Seal: FPM (EPDM optional), Length: 69 mm, Viscosity: 0.8-10 cSt, K-Factor: approx. 100,000
Turbine flow sensor, Internal diameter: 50 mm, Linear measurement range: 113 – 1,133 l/min, Measurement accuracy: 0.5% of the measured value at 1-5 cSt, Material in contact with the medium: stainless steel/ceramic (wolfram carbide), Viscosity linear range: 1 – 5 cSt, Other viscosities: 8/12/20 cst, Output module: IC-MV-PO with PNP/NPN, Cable length: 5 m