Capacitive point level detector: Probe length: 140 mm, Output: 3-wire PNP/relay, Process pressure range: -1–25 bar, Process temperature range: -40–120°C, Enclosure material: aluminium/polyester, Protection rating: IP66
Vibronic point level detector: Probe length: 225 mm, Output: 3-wire PNP/relay DPDT, Process pressure range: -1–40 bar, Power supply: 1–45 V DC/19–253 V AC, Process temperature range: -40–150°C, Probe material: stainless steel (1.4404/316 L), Enclosure material: aluminium/polyester, Protection rating: IP66/IP67
Vibronic point level detector, Output: 2-wire/3-wire PNP/4-wire DC-PNP, Process pressure range: -1–40 bar, Power supply: 20–253 V AC/DC or 10–30 V DC, Process temperature range: -40–150°C, Protection rating: IP65/IP67 - IP66/IP68/IP69K - IP65 - IP66/IP68
Vibronic point level detector, Output: 2-wire AC/DC or 3-wire DC-PNP or 4-wire DC-PNP with IO-Link,, Process pressure range: -1–40 bar, Power supply: 20–253 V AC/DC or 10–30 V DC, Process temperature range: -40–150°C, Protection rating: IP65/IP67 - IP66/IP68/IP69K - IP65 - IP66/IP68
Point level detector, Media: liquid, Output: PNP/3-wire, Process connection: G 3/4 (316L), Medium density: > 0.7 g/cm³, Power supply: 10–30 V DC, Process temperature range: -40–100 °C, Process pressure range: -1–40 bar, Enclosure material: stainless steel (316L), Protection rating: IP65, Connection: M16 valve connector ISO4400
Point level detector, Media: liquid, Output: PNP/3-wire, Process connection: G 1/2 (316L), Medium density: > 0.7 g/cm³, Power supply: 10–30 V DC, Process temperature range: -40–100 °C, Process pressure range: -1–40 bar, Enclosure material: stainless steel (316L), Protection rating: IP65, Connection: M16 valve connector ISO4400
Point level detector, Media: liquid, Output: PNP/3-wire, Process connection: G 3/4 (316L), Medium density: > 0.7 g/cm³, Power supply: 10–30 V DC, Process temperature range: -40–150 °C, Process pressure range: -1–40 bar, Enclosure material: stainless steel (316L), Protection rating: IP65/IP67, Connection: M12 cable gland
Point level detector, Media: liquid, Output: PNP/3-wire, Process connection: G 1 (316L), Medium density: > 0.7 g/cm³, Power supply: 10–30 V DC, Process temperature range: -40–150 °C, Process pressure range: -1–40 bar, Enclosure material: stainless steel (316L), Protection rating: IP65, Connection: M16 valve connector ISO4400
Point level detector, Media: liquid, Output: PNP/3-conductor, Process connection: G 3/4 (316L), Medium density: > 0.7 g/cm³, Power supply: 9.6-35 V DC, Process temperature range: -40-100 °C, Process pressure range: -1-64 bar, Enclosure material: stainless steel (316L), Protection rating: IP65/IP67, Connection: M12 connector
Point level detector, Media: liquid, Output: PNP/3-conductor, Process connection: G 1/2 (316L), Medium density: > 0.7 g/cm³, Power supply: 9.6-35 V DC, Process temperature range: -40-100 °C, Process pressure range: -1-64 bar, Enclosure material: stainless steel (316L), Protection rating: IP65, Connection: valve connector (ISO4400)
Point level detector, Media: liquid, Output: PNP/3-conductor, Process connection: G 1/2 (316L), Medium density: > 0.7 g/cm³, Power supply: 9.6-35 V DC, Process temperature range: -40–100 °C, Process pressure range: -1-64 bar, Enclosure material: stainless steel (316L), Protection rating: IP65/IP67, Connection: M12 connector
Point level detector, Media: liquid, Output: PNP/3-conductor, Process connection: G 3/4 (316L), Medium density: > 0.7 g/cm³, Power supply: 9.6–35 V DC, Process temperature range: -40–100 °C, Process pressure range: -1-64 bar, Enclosure material: stainless steel (316L), Protection rating: IP65, Connection: valve connector (ISO4400)
Point level detector, Media: coarse-grained bulk goods, Output: PNP/NPN transistor, Process pressure range: -1-60 bar, Process connection: G 1, Medium density: min. 100 g/l, Sensor length: 148 mm, Supply voltage: 10-55 V DC, Process temperature range: -50-150 °C, Enclosure material: plastic, Protection rating: IP66/IP67, Connection: M20 cable gland
Point level detector, Media: liquid, IO-Link, Output: PNP/4-wire, Process connection: G 1/2 (316L), Medium density: > 0.7 g/cm³, Power supply: 10–30 V DC, Process temperature range: -40–150 °C, Process pressure range: -1–40 bar, Enclosure material: stainless steel (316L), Protection rating: IP65/IP67, Connection: M12 cable gland
Point level detector, Media: bulk solids, Output: PNP/3-wire, Process pressure range: -1–25 bar, Process connection: R 1 1/2, Medium density: min. 200 g/l, Power supply: 10–45 V DC, Process temperature range: -40–150 °C, Enclosure material: aluminium, Protection rating: IP66/IP67, Connection: M20 cable gland
Point level detector, Media: bulk solids, Output: relay DPDT, Process pressure range: -1–25 bar, Process connection: R 1, Medium density: min. 200 g/l, Power supply: 10–45 V DC, Process temperature range: -40–150 °C, Enclosure material: aluminium, Protection rating: IP66/IP67, Connection: M20 cable gland
Point level detector, Media: powder-form and fine-grained bulk goods, Output: PNP/NPN transistor, Process pressure range: -1-25 bar, Process connection: G 1 1/2, Medium density: min. 100 g/l, Sensor length: 165 mm, Supply voltage: 10-55 V DC, Process temperature range: -50-150 °C, Enclosure material: plastic, Protection rating: IP66/IP67, Connection: M20 x 1.5 cable gland
Point level detector, Media: powder-form and fine-grained bulk goods, Output: 2 x DPDT relays, Process pressure range: -1-25 bar, Process connection: G 1 1/2, Medium density: min. 100 g/l, Sensor length: 165 mm, Supply voltage: 20-253 V AC/20-72 V DC, Process temperature range: -50-150 °C, Enclosure material: plastic, Protection rating: IP66/IP67, Connection: M20 x 1.5 cable gland
Point level detector, Media: liquid, Output: PNP/3-conductor, Process connection: G 3/4 (316L), Medium density: > 0.7 g/cm³, Rod length: 150 mm, Power supply: 9.6–35 V DC, Process temperature range: -40–100 °C, Process pressure range: -1-64 bar, Enclosure material: stainless steel (316L), Protection rating: IP67, Connection: valve connector (ISO4400)
Point level detector, Media: coarse-grained bulk goods, Output: PNP/NPN transistor, Process pressure range: -1-60 bar, Process connection: G 1, Medium density: min. 100 g/l, Sensor length: 148 mm, Supply voltage: 10-55 V DC, Process temperature range: -50-150 °C, Enclosure material: plastic, Protection rating: IP66/IP67, Connection: M20 cable gland, ATEX-approved
Point level detector, Media: powder-form and fine-grained bulk goods, Output: PNP/NPN transistor, Process pressure range: -1-25 bar, Process connection: G 1 1/2, Medium density: min. 100 g/l, Sensor length: 165 mm, Supply voltage: 10-55 V DC, Process temperature range: -50-150 °C, Enclosure material: plastic, Protection rating: IP66/IP67, Connection: M20 x 1.5 cable gland, ATEX-approved
Point level detector, Media: liquid, Output: PNP/3-conductor, Process connection: G 3/4 (316L), Medium density: > 0.7 g/cm³, Rod length: 100 mm, Power supply: 9.6–35 V DC, Process temperature range: -40–100 °C, Process pressure range: -1-64 bar, Enclosure material: stainless steel (316L), Protection rating: IP65, Connection: valve connector (ISO4400)
Point level detector, Media: liquid, Output: PNP/3-conductor, Process connection: G 3/4 (316L), Medium density: > 0.7 g/cm³, Rod length: 200 mm, Power supply: 9.6–35 V DC, Process temperature range: -40–100 °C, Process pressure range: -1-64 bar, Enclosure material: stainless steel (316L), Protection rating: IP65, Connection: valve connector (ISO4400)
Point level detector, Media: coarse-grained bulk goods, Output: DPDT relay, Process pressure range: -1-60 bar, Process connection: G 1, Medium density: min. 100 g/l, Sensor length: 148 mm, Supply voltage: 20-253 V AC/20-72 V DC, Process temperature range: -50-150 °C, Enclosure material: plastic, Protection rating: IP66/IP67, Connection: M20 x 1.5 cable gland, ATEX-approved
Point level detector, Media: liquid, Output: PNP/3-wire, Process connection: G 1, Medium density: > 0.7 g/cm³, Power supply: 10–30 V DC, Process temperature range: -40–150 °C, Process pressure range: -1–40 bar, Enclosure material: stainless steel (316L), Protection rating: IP65/IP67, Connection: M12 cable gland